2010-04-29

Modern hotel installs the most modern room controller.
However, it is far more than aesthetics which is characterized by quality and thoughtful planning at the Clarion Hotel, Västerås.

The choice of technology to control the indoor climate and energy management has also been given high priority.

All rooms have controlled zones that give their users the opportunity to adjust the temperature.

The installed zone system takes care of the indoor climate.

     

Operation card

 

 

 

 

   

Clarion Collection, Västerås


2010-04-23

Great potential for saving energy in parking garages
Automatic control of ventilation in parking garages saves a great deal of money while giving alarm for toxic gases.

Demand controlled ventilation for parking garages becomes economically advantageous in virtually all applications and generates in most cases an energy gain after a few months.

More

 

       

 

 

 

 

Proj.hints
Garages

Energy saving


2010-03-10

Detectors from AP warns of ammonia before concentration reaches health risk level.

The good part about ammonia leakage is that people notice small amounts by the unpleasant smell.

The NH3 detector from the AP monitors ammonia in very small quantities.

The new ammonia detector measures down to 10 ppm and thus meets the requirements of the Work Environment Authority to give alarm at:

  • Level value 25ppm (the concentration that a person may be exposed to during an 8 hour day without the fear of health hazards)

  • Major alarm at max. level (maximum exposure time 5 min.) 50 ppm

Given these rules, two thresholds are monitored.

  1. The first alarm alerts the technical staff and starts the ventilation system (if available).

  2. Alarm for rising concentrations leads to the machine shut downs and the local emergency services are contacted.

The sensitive sensor can distinguish at low concentrations and respond rapidly. Response time is 35 seconds.

Detection range for this application is 0-100ppm. The application has a high accuracy of 4 ppm.

Operating temperature is -10° C ... +40° C and with internal heating elements down to minus 30° C.

More on detectors for ammonia leakages


Ammonia detector with display


2009-12-11

Reliable measurement data for Energy Performance Contracting
A sun-ray protection, protecting outdoor-mounted temperature sensors from sporadic or direct solar radiation as well as the influence of heat from walls and ground, with a guarantee for reliable measurements of temperature control for energy efficiency in buildings.
 
WSS is a naturally ventilated sun-ray protection complete with accessories to provide a simple installation of humidity and temperature sensors.
 
Temperature sensors according to protection class IP65 are available with different measuring elements to be integrated in the control and automation system of the EPC.
 
For maximum protection, the screens' outer surfaces are white in order to reflect radiation. This gives very good outdoor measurement results.
 
The screen plates are made of a special material providing an excellent heat and UV stabilized function.

See Weather Station - Standard

PS: The EPC is an effective model for reducing energy consumption and environmental impact in all types of properties.
 
You should also use the WSS sun-ray protection


2009-12-02
Parking Garages consume a great amount of energy
The reason that energy consumption is high in garages and Parking garages is because heating and ventilation systems are in operation 24 hours a day.

Cutting operating costs by using gas detectors makes it possible for property owners to quickly obtain substantially reduced energy costs.

Gas detectors can control the speed of fans, such as by using  DUC / PLC or frequency converters depending on traffic intensity.

Automatic control of ventilation saves both a great amount of money while it at the same time giving alarm for toxic gases.

Ps. Parking garages can be a real money-box! You can even cut on heating costs!!!

See


2009-11-22
Save on energy consumption in hotels

Would you like to save energy in unoccupied hotel rooms?

The Oden energy monitoring system was delivered to the apartment hotel "Träslöjden" in Hammarby Sjöstad!

If you let the Oden control the energy consumption in hotel rooms the consumption will be considerably reduced and create good conditions for future energy certification of your property.

By integrating an occupancy detector or a signal via the hotel´s reception desk to the MPC controller for the cooling / heating mode "hotels", cooling/heating will automatically be changed according to requirements and also turn on the lights when the guest enters his/her room.

 

When the hotel guest has checked out the room, the temperature is regulated to a level of energy conservation for empty rooms.

Every day, the hotels pay for energy which is not used or needed by the guests.

Ps. The Oden can be used to control almost all types of heating, ventilation, lighting or floor heating that is available on the market today.

 

 

2009-11-10
On Demand Controlled Lighting - Quick return of investment


In recent years, property owners, businesses, municipalities and other public institutions realize the benefits of planning their lighting.

In many offices, it is possible to reduce energy consumption from lighting by up to 70%, which means that the investment cost is very quickly earned and instead start saving money.

In addition to saving money, a review of the lights can also create a better working environment.

To achieve savings as huge as indicated above, a good lighting plan is needed with some sort of control system.

With a balanced control system connected to the light  detectors, which turns off lights when there is nobody in the room, we can save even more energy

These systems can also function at different levels, where you can gradually control the luminosity and then completely turn the light off. See the following links:



 


2009-11-10
Efficient use of energy in the room with optimum indoor comfort


The MPC Combi Combi Controller links the building's technical functions such as lighting, heating/cooling, VAV, ventilation, emergency/monitoring, sunscreen, CO2 and other features. As standard it is fitted with a open communication system designed to be connected to the BMS controller or the Web.

Settings are made with the keypad on the controller or the setup programme "MPC Manager" which is supplied free of charge.

Benefits of the MPC-Combi Controller:

  • Simplified wiring

  • Clear display that shows current temperature

  • Reduces energy costs through tailored control, regulation of lighting, heating/cooling and ventilation.

  • Universal I/O for analog and digital measurement and control signals as well as relay outputs.

  • Local settings are made with the keypad on the controller for setting and adjusting the operating sequences, etc.

  • Keypad and logotype can be adapted to different projects.

  • The Intelligence is available in each MPC Combi controller and through amplifiers 247 units can be up to installed in a Modbus network.

 

         
     

OR485MPC

MPC

 

 

 

 

   

Inkoppling

Zone Controller

The MPC is used in larger installations requiring high functionality, for example, offices, schools, churches, industry, flats, public places where building and integration between different property features are important, as well as in advanced facilities in villas as stand alone systems.

The MPC Combi controller can be delivered pre-programmed with desired function.

   

E-mail: lars@fjellcom.se     

Phone: +46(0)31-287202

Mobile: +46(0)706-755561